Mud Engineer / Hydraulics Studio
ME
Engineering workspace

Hydraulics Studio

Build a well case, check volumes and survey geometry, and prepare a clear report. Pressure simulation is unavailable.

● Pressure engine locked
Your active case

New hydraulics case

Well not set · Fluid not set
Draft
Input readiness0%Required fields checked
Geometry sections0Wellbore intervals
Survey stations0MD entries

Case workflow

A guided path from inputs to report
6 steps
1
Case detailsWell, job, units
2
Well path & geometrySurvey, hole and string
3
Fluid & conditionsRheology and pump inputs
4
Review inputsCompleteness and warnings
5
Geometry checksVolumes and survey cross-checks available
6
ReportPreview and print

Wellbore at a glance

Schematic orientation only
Not to scale
Well path not enteredSurface ↓ measured depth

Calculation status

Geometry checks are available; pressure hydraulics are locked
Validation required
⚠
Engineering results are disabled.
A qualified engineer must approve the licensed method and verify benchmark cases before this app can show pressure-loss or ECD results.
Your case data can still be entered, saved, reviewed, and included in a draft report.
Step 1 of 4 · Case

Set up your case

Give the run a clear identity and choose the unit system for data entry.

Autosaves on this device
Case workflow

Case identity

These details appear on saved cases and reports.
Step 1
Switching units converts supported values. Check imported or older drafts against their source units.
Step 2 of 4 · Well path

Well & geometry

Enter depth stations and each section of the flow path. Keep source units consistent.

0 geometry rows
Case workflow

Well path / survey stations

MD and inclination are required for a usable survey record.
StationMDTVD (entered)InclinationAzimuthComment
No survey stations yet. Paste survey rows from Excel or add a station manually.

Flow-path geometry

Add intervals from surface toward bit; record dimensions as supplied by the program.
Flow pathComponentTop MDBottom MDOuter diameterInner diameter
No geometry entered. Use one row per distinct interval or component.
ⓘ
For Annulus, use hole/casing ID as Outer diameter and pipe OD as Inner diameter. For Inside string and Surface line, enter the actual component OD and bore ID.

Volumes & survey check

Calculated from entered geometry and survey stations; no pressure or flow simulation.
Geometry math
Annular volume—bbl
Inside-string capacity—bbl
Surface-line capacity—bbl
Tubular steel displacement—bbl
Total entered system volume—bbl
ⓘ
Add complete, connected annulus and inside-string intervals that reach the entered bit depth to calculate whole-well volumes.
Add at least two complete survey stations to calculate the minimum-curvature cross-check.
ft
ft
in²
Step 3 of 4 · Fluid & operation

Fluid & conditions

Enter measured fluid data and the operating point for the case.

Retain raw test readings
Case workflow

Fluid properties

Enter measured values; do not replace measurements with fitted coefficients.
ppg
°F

Viscometer readings

Record instrument speed and dial readings exactly as tested.
°F
psi

Operating conditions

Use a consistent operating snapshot for each scenario.
gpm
psi
hr
°F
°F
psi
psi
rpm
ⓘ
Optional data is not used to generate engineering output in this prototype. Model applicability and required inputs must be defined by the approved calculation method.
Step 4 of 4 · Input review

Review & run

Resolve missing inputs and warnings before any approved calculation is run.

Engineering engine unavailable
Case workflow

Input readiness

Completeness checks only; passing these does not prove the model is valid.
0% ready

Calculation gate

No pressure hydraulics are calculated by this design prototype.
Locked
🔒

Pressure-hydraulics results are not enabled

Before activation, an engineer must approve the calculation method, its licensed references, model limits, independent expected-value cases, and A2Z comparisons. This button will not create or display pressure, ECD, HHP, or flow-regime values.

Output · Report builder

Build a draft report

Choose sections, review the case snapshot, then print or save as PDF from your browser.

MUD ENGINEER · HYDRAULICS STUDIO

Hydraulics Case Report

Geometry checks only · pressure hydraulics unavailable
GEOMETRY CHECK · HYDRAULICS LOCKED

Case summary

Case: Not entered

Well: Not entered · Job: Not entered

Fluid: Not entered · Units: Field

Prepared by: Not entered · Date: Not entered

Operating snapshot

Mud density: Not entered · Flow rate: Not entered

Bit depth: Not entered · Hole depth (TVD): Not entered

Rheology model: Not entered · Surface back pressure: Not entered

Input quality

0% completeness checks passed. See the selected sections for entered data and missing fields.

Engineering status

Geometry calculations: Entered-path volumes and a minimum-curvature survey cross-check are shown when required inputs are complete.

Pressure loss / ECD / HHP / transients: Not calculated. The pressure-hydraulics method remains locked pending engineering review and independent validation.

Use restriction: Geometry checks only; no operational pressure or flow result. Verify all inputs independently.

Entered inputs

No additional inputs entered.